Test System for Conducted and Radiated Immunity
35 W, 150 kHz to 230 MHz;
40 W, 10 kHz to 400 MHz;
45 W, 9 kHz to 1 GHz;
60 W, 10 kHz to 400 MHz
(>10 W, 4 kHz to 10 kHz);
80 W, 150 kHz to 230 MHz
Technical Parameters:
Frequency range: 9 kHz – 1 GHz
Resolution: 1 Hz
Reference frequency: Reference frequency output: 10 MHz
Level range: -60 dBm – +10 dBm
Resolution: 0.1 dB
Setting time: 10 ms
Depth of modulation: 0 – 100%
Modulation frequency range: 1 Hz – 50 kHz
Frequency resolution 1 Hz
Rise/fall time (10%/90%): < 1 μs
Modulation frequency range: 1 Hz – 50 kHz
Frequency resolution: 1 Hz
Duty cycle: 10% – 90%
Features:
NSG 4070, an improved version of the NSG 2070 - a versatile EMC immunity test system. The NSG 4070 has a very wide frequency range (from 9 kHz to 1 GHz), a module structure using external or internal amplifiers, so it has a wide range of applications: including tests according to IEC 61000-4-6, various types of Current injection applications, such as signal generators and power meters for test systems in IEC 61000-4-3, IEC 61000-4-20, IEC 61000-4-21 applications. Thanks to its powerful and easy-to-use firmware, the NSG 4070 can work independently without an external computer and control software. Of course, remote control can also be used for system operation. By inserting the USB memory into the panel, the latest test and measurement data can be transmitted and saved to generate a test report.
應用標準: