Charge/Discharge Test System – 9220 Series
Automated Characterization, Battery Cycler, Power Cycling, & Life-Cycle Testing of Low Voltage/High Current Batteries
Features
-
Single output up to 40V/3,600A/72kW per system
-
Parallel expansion up to 7,200A
-
Built-in digital measurements including Ah & kWh
-
Multiple safety layers to protect battery/DUT
-
SCPI, VXI-11, & LabVIEW control via LAN interface
-
NI-Compliant LabVIEW Drivers
-
Regenerative, 87% efficiency returning discharge power to facility
-
Crane/hoist lifting hangers & robust casters
9220 Series Dual Bay Specifications
Model #
|
9220-4904-48
|
9220-4904-60
|
9220-4904-72
|
Voltage
|
0 – 40V
|
0 – 40V
|
0 – 40V
|
Current
|
±2400A
|
±3000A
|
±3600A
|
Discharge Power
|
48kW
|
60kW
|
72kW
|
Charge Power
|
32kW
|
40kW
|
48kW
|
Physical
|
|
|
|
Size (HxWxD)
|
83.25 x 56.56 x 34.5″/2115 x 1437 x 876mm
|
Weight
|
2150lbs/975kg
|
2450lbs/1111kg
|
2750lbs/1247kg
|
Advantages
-
Low voltage/high current battery cycler
-
Designed for testing all battery chemistries including:
– Lead-acid
– Lead-cadmium
– Other low voltage, high current batteries
-
Multiple safety layers to protect battery/DUT
Benefits
-
Regenerative, returns greater than 87% of power to the facility, which provides significant electrical savings.
-
Bi-directional system requiring no additional equipment to charge or discharge the unit-under-test (UUT)
-
The built-in measurement system eliminates external measurement devices
-
Regenerative, recycles up to 87% discharge power back to the facility
-
System cabinet features for easy installation
Applications
The 9220 Low Voltage/High Current Battery Cycler is designed for
testing all battery chemistries including lead-acid, lead-cadmium, and
other low voltage, high current, large format batteries (LFB) typically
used in energy storage systems (ESS). The system is bi-directional
requiring no additional equipment to charge or discharge the
unit-under-test (UUT). Additionally, the built-in measurement system
eliminates external measurement devices by providing time-stamped
digital readings for voltage, current, power as well as Ah and kWh.